APPLICATION_12 · FACILITIES

Server room monitoring

Watch the room around your racks — leak, climate, cabinet temperature and smoke risk — and alert the team before equipment is at risk.

Water leakAmbient temp & humidity24-hour mobile app alerts

How it helps

Fewer blind spots between walk-throughs

The pain today

  • A server room is often lightly staffed overnight and at weekends.
  • There are gaps between walk-throughs.

How this helps

  • Continuous sensing fills the gaps between walk-throughs.
  • Leak, heat or smoke events are noticed sooner and the response trail is clearer.
01

Earlier notice

Alert when temperature or humidity leaves the band you set, or when a leak or smoke event is raised — overnight, weekends and between rounds.

02

Clearer hand-offs

The same reading, alert and history are available to the facilities and IT roles you assign on the dashboard.

03

Reviewable records

Event history and trends support day-to-day operations and later review — without inventing certification claims.

Operating flow

From measurement to action

Sensors can connect over LoRaWAN or NB-IoT. An NB-IoT sensor is an alternative to a LoRaWAN sensor: with NB-IoT you do not need a LoRaWAN gateway, but each sensor needs an NB-IoT SIM card. The LoRaWAN path still uses a gateway. NB-IoT is not supported in Macau — use LoRaWAN there. The WSmart mobile app delivers alert notifications and live status, with 24-hour continuous monitoring.

WSmart server room monitoring — water leak, ambient temperature and humidity, rack or bus-bar temperature, smoke detector and buzzer; LoRaWAN or NB-IoT, cloud, mobile app alerts and 24-hour status
Diagram shows the LoRaWAN path (sensors → gateway → cloud). NB-IoT sensors are an alternative: no LoRaWAN gateway needed; each sensor needs an NB-IoT SIM card.
  1. 01

    Sense

    Water leak, ambient temperature and humidity, rack or bus-bar temperature, smoke detection where the site needs it, and an on-site buzzer — placed around the server room and cabinets.

  2. 02

    Connect

    Uplink via a LoRaWAN gateway path, or use NB-IoT sensors instead — no LoRaWAN gateway needed, but each NB-IoT sensor needs its own SIM card. Either path reaches the WSmart platform without heavy rewiring around racks.

  3. 03

    Alert

    When a reading leaves the set band, or a leak or smoke event is raised, notify via the mobile app, SMS, WhatsApp, email or buzzer.

  4. 04

    Review

    Check live status and history in the app or dashboard anytime — monitoring runs around the clock.

At a glance

A practical package for the room around the racks

01

Climate and leak

Ambient Temp / Humidity Sensor (−20 to 60°C, up to 5 years battery) plus Water Leakage sensing (analog level measurement, leakage and cable-break alert, up to 5 years battery) for the room, raised floor or pipe runs.

02

Rack and bus-bar temperature

Hardware lists bus-bar temperature as a use case of the Ambient Temp / Humidity Sensor. The published range is −20 to 60°C. No separate extreme-temperature SKU is listed on the current catalogue.

03

Alerts your team already uses

Route alerts by SMS, WhatsApp, email, app or on-site buzzer so facilities or IT staff can act when a reading leaves the set band, or a leak or smoke event is raised.

What the solution does

From a room reading to a clear response

FEATURE_01

Room climate and leak

Set high and low limits for ambient temperature (published range −20 to 60°C) and watch humidity and leak state in the same room view.

FEATURE_02

Rack and cabinet temperature

Add bus-bar or cabinet temperature points where the site needs them. The catalogue files this use case under the Ambient Temp / Humidity Sensor; a wider-range probe, if needed, is confirmed at assessment.

FEATURE_03

Multi-channel notify

Send the alert to the right role through SMS, WhatsApp, email, app or buzzer — the same alert channels used across WSmart.

FEATURE_04

Wireless LoRaWAN or NB-IoT

Battery sensors can report over LoRaWAN (via a gateway) or NB-IoT (each sensor needs an NB-IoT SIM; no LoRaWAN gateway on that path). NB-IoT is not supported in Macau — use LoRaWAN there. Add monitoring without heavy rewiring around racks.

Hardware in this package

Sensors

The devices below are shown with the specs published on the Hardware page, except where we say a model is confirmed at assessment. No invented SKUs, ranges or product photos.

Water leakage sensor device

Water Leakage

For raised floors, condensate lines and pipe runs around the server room.

  • •Analog level measurement
  • •Up to 5 years battery life
  • •Leakage and cable-break alert
Ambient temperature and humidity sensor device

Ambient Temp / Humidity Sensor

Room-level climate around the racks.

  • •Temp range: −20 to 60°C
  • •Up to 5 years battery life
  • •Over / under threshold alert
On-site buzzer / siren device

Buzzer

Smart wireless alarm that can communicate with other devices through a wireless network. It has a high-decibel speaker and high-brightness LED which can realize sound and light alarms.

  • •Power supply: DC 12V adapter, with 3 AAA Ni-MH rechargeable batteries (1.2V/section) connected in series as backup
  • •Backup rechargeable battery: about 24 hours once fully charged
  • •Alarm sound: ≥80 dB
  • •LoRaWAN Class C
Smoke detector device

Smoke detector

On-site smoke sensing for the server room, used where the site needs smoke alerts. Smoke alerts are mentioned as a capability on the Hardware page (critical case management).

Water leak sensor with a yellow sensing rope, a black leading cable, and the main sensor box

Optional: Water Leak sensor with water rope

  • •LoRaWAN: AS923
  • •Power: 3.6V C-Size ER26500 Battery
  • •Sensing Cable: 10-meter
  • •Leading Cable: 3-meter
  • •Data Upload Interval: 1 Hour (configurable)
  • •Instant Alert Notification: Alert trigger when water leakage detected
  • •Battery Life: >10-year
  • •Sensor Body Dimension: 112 x 70 x 39 mm

See Sensor Integration on Hardware →

Need another sensor? Contact us on Hardware →

Connectivity can use LoRaWAN (via a wireless gateway) or NB-IoT sensors (each needs an NB-IoT SIM; no LoRaWAN gateway on that path) — no invented gateway SKU. NB-IoT is not supported in Macau; use LoRaWAN there. This package does not invent external regulatory certifications.

Where it fits

Typical sites in HK, Macau and Malaysia

Two colleagues talking in a glass-walled office, one holding an open laptop
USE_01

Office and building server rooms

A compact rack room in a commercial or residential building, watched by facilities and IT between walk-throughs.

A person typing on a laptop in front of a server rack densely wired with white cables
USE_02

Retail, mall and branch comms rooms

Small communications or server closets that are easy to miss outside opening hours.

A woman working at a row of desktop computers in a monitoring room
USE_03

Campus, hospital and clinic IT rooms

Department-level server or comms rooms as a sensor package — not a whole-campus BMS replacement.

A server cabinet with a row of blue patch cables above stacked servers
USE_04

Small rack suites

A short row of cabinets where leak, climate and cabinet temperature need to be visible. This is not a full data-centre DCIM or Energy Saving Solution (DCD) package.

Dashboard view

Make server-room status visible when it matters

Configure roles, thresholds, locations and escalation rules for your facilities or IT team. Start with the points below, then tailor the view.

  • •Ambient temperature and humidity
  • •Water leak state
  • •Rack / bus-bar temperature
  • •Smoke alert state, when a detector is included
  • •Battery level and last heartbeat
  • •Location, event history and trends

FAQ

Server room monitoring FAQ

What does this server room package monitor?

The package is built around water leak sensing, ambient temperature and humidity, rack or bus-bar temperature, an on-site buzzer, and smoke detection where the site needs it. Alerts can go to the mobile app, SMS, WhatsApp, email or buzzer, with live status and history on the WSmart dashboard and 24-hour monitoring.

What temperature range is published for ambient and bus-bar sensing?

The Ambient Temp / Humidity Sensor listed on WSmart Hardware is specified at −20 to 60°C, with over and under threshold alerts and up to 5 years battery life. Hardware also shows “Bus Bar Temperature” as a use case of that same sensor. No separate extreme-temperature SKU is listed on the current catalogue. If a site needs a wider range, the model is fixed in the assessment.

Is a smoke detector included as a catalogue SKU?

No. Smoke alerts are mentioned as a capability on the Hardware page, but the current Hardware catalogue does not list a smoke-detector SKU. A product photo is shown on this page for the detector used in the package; no SKU or published range is invented.

Is this a full data-centre BMS or DCIM platform?

No. This is a wireless sensor package for a server room or small rack suite — leak, climate, rack or bus-bar temperature, smoke detection where included, alerts, dashboard views and history logs. Larger building BMS or data-centre energy work is covered under separate BMS hybrid, retrofit and Energy Saving Solution (DCD) applications.

Can we use LoRaWAN or NB-IoT sensors?

Yes. An NB-IoT sensor is an alternative to a LoRaWAN sensor. If you use NB-IoT sensors, you do not need a LoRaWAN gateway, but each sensor needs an NB-IoT SIM card. The LoRaWAN path still uses a gateway. NB-IoT is not supported in Macau — use LoRaWAN there. The WSmart mobile app supports alert notifications and status checks, with 24-hour continuous monitoring.

How do teams get alerts?

WSmart can send the alert to the right role through SMS, WhatsApp, email, app or an on-site buzzer. Thresholds and escalation rules are configured on the dashboard.

Next step

Book a site assessment

Tell us the room layout, how many racks you need to cover, and who should get alerts. We will come back with an assessment for Hong Kong, Macau or Malaysia.

Book a site assessment
    Contact us on WhatsApp